<?xml version="1.0" encoding="utf-8"?>
<!-- generator="Joomla! - Open Source Content Management" -->
<feed xmlns="http://www.w3.org/2005/Atom"  xml:lang="fr-fr">
	<title type="text">Panoply - T3.4 Reconstitution des paléoenvironnements continentaux</title>
	<subtitle type="text">PANOPLY met à la disposition de la communauté scientifique académique et industrielle l'éventail des ressources de hautes technologies du Plateau de Saclay dans le domaine des sciences de la Terre, du Climat et de l’environnement.</subtitle>
	<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr"/>
	<id>https://panoply-geops.lsce.ipsl.fr/index.php/thematiques-scientifiques/les-fiches-par-thematique/t3-paleoclimatologie-et-paleoceanographie-1/t3-4-reconstitution-des-paleoenvironnements-continentaux</id>
	<updated>2026-06-19T16:35:55+00:00</updated>
	<author>
		<name>Panoply</name>
		<email>nada.caud@lsce.ipsl.fr</email>
	</author>
	<generator uri="https://www.joomla.org">Joomla! - Open Source Content Management</generator>
	<link rel="self" type="application/atom+xml" href="https://panoply-geops.lsce.ipsl.fr/index.php/thematiques-scientifiques/les-fiches-par-thematique/t3-paleoclimatologie-et-paleoceanographie-1/t3-4-reconstitution-des-paleoenvironnements-continentaux?format=feed&amp;type=atom"/>
	<entry>
		<title>δ13C et δ18C dans la cellulose et le bois</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/286-%CE%B413c-et-%CE%B418c-dans-la-cellulose-et-le-bois"/>
		<published>2015-06-08T10:48:39+00:00</published>
		<updated>2015-06-08T10:48:39+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/286-%CE%B413c-et-%CE%B418c-dans-la-cellulose-et-le-bois</id>
		<author>
			<name>Jacob</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Vario PYRO cube - Isoprime PrecisION, Elementar&lt;sup&gt;®&lt;/sup&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Photo2-PrecisION.png&quot; alt=&quot;Photo2 PrecisION&quot; width=&quot;300&quot; height=&quot;225&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument :&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse à secteur magnétique isoprime PrecisION (Elementar&lt;sup&gt;®&lt;/sup&gt;) couplé à un analyseur élémentaire à Haute température vario PYRO cube (Elementar&lt;sup&gt;®&lt;/sup&gt;).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les échantillons solides (pesés dans des capsules en argent) subissent une pyrolyse à 1400°C. Ils sont convertis en CO gazeux. Le gaz échantillon est ensuite introduit dans la source du spectromètre sous flux d’hélium et est analysé par rapport à un gaz CO standard commercial.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les molécules du gaz sont ionisées dans la source, accélérées par un champ électrique et déviées en fonction de leur masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 28, 29 et 30.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;13&lt;/sup&gt;C and δ&lt;sup&gt;18&lt;/sup&gt;O sont déterminés simultanément à partir du même échantillon avec une précision&amp;nbsp; de 0.15‰ pour δ&lt;sup&gt;13&lt;/sup&gt;C et 0.30‰ pour δ&lt;sup&gt;18&lt;/sup&gt;O (voir Loader et al. 2014, pour une description de la méthode&amp;nbsp;: DOI: 10.1021/ac502557x).&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Rapports des isotopes stables du carbone et de l’oxygène dans la cellulose et le bois&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Financements :&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Projet &lt;strong&gt;:&lt;/strong&gt; RIOCAS, IDF-DIM-MAP-2021-3-001&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Monique Pierre : 01.69.08.31.20 / &lt;a href=&quot;mailto:monique.pierre@lsce.ipsl.fr&quot;&gt;monique.pierre[a]sce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Michel Stievenard : 01.69.08.71.70 / &lt;a href=&quot;mailto:michel.stievenard@lsce.ipsl.fr&quot;&gt;michel.stievenard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Vario PYRO cube - Isoprime PrecisION, Elementar&lt;sup&gt;®&lt;/sup&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Photo2-PrecisION.png&quot; alt=&quot;Photo2 PrecisION&quot; width=&quot;300&quot; height=&quot;225&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument :&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse à secteur magnétique isoprime PrecisION (Elementar&lt;sup&gt;®&lt;/sup&gt;) couplé à un analyseur élémentaire à Haute température vario PYRO cube (Elementar&lt;sup&gt;®&lt;/sup&gt;).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les échantillons solides (pesés dans des capsules en argent) subissent une pyrolyse à 1400°C. Ils sont convertis en CO gazeux. Le gaz échantillon est ensuite introduit dans la source du spectromètre sous flux d’hélium et est analysé par rapport à un gaz CO standard commercial.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les molécules du gaz sont ionisées dans la source, accélérées par un champ électrique et déviées en fonction de leur masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 28, 29 et 30.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;13&lt;/sup&gt;C and δ&lt;sup&gt;18&lt;/sup&gt;O sont déterminés simultanément à partir du même échantillon avec une précision&amp;nbsp; de 0.15‰ pour δ&lt;sup&gt;13&lt;/sup&gt;C et 0.30‰ pour δ&lt;sup&gt;18&lt;/sup&gt;O (voir Loader et al. 2014, pour une description de la méthode&amp;nbsp;: DOI: 10.1021/ac502557x).&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Rapports des isotopes stables du carbone et de l’oxygène dans la cellulose et le bois&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Financements :&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Projet &lt;strong&gt;:&lt;/strong&gt; RIOCAS, IDF-DIM-MAP-2021-3-001&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Monique Pierre : 01.69.08.31.20 / &lt;a href=&quot;mailto:monique.pierre@lsce.ipsl.fr&quot;&gt;monique.pierre[a]sce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Michel Stievenard : 01.69.08.71.70 / &lt;a href=&quot;mailto:michel.stievenard@lsce.ipsl.fr&quot;&gt;michel.stievenard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="δ13C et δ18C dans la cellulose et le bois" />
	</entry>
	<entry>
		<title>δ13C dans la cellulose et le bois</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/287-%CE%B413c-dans-la-cellulose-et-le-bois"/>
		<published>2015-06-08T10:48:39+00:00</published>
		<updated>2015-06-08T10:48:39+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/287-%CE%B413c-dans-la-cellulose-et-le-bois</id>
		<author>
			<name>Jacob</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Vario MICRO cube - Isoprime, Elementar&lt;sup&gt;®&lt;/sup&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Photo1-ISOPRIME.png&quot; alt=&quot;Photo1 ISOPRIME&quot; width=&quot;300&quot; height=&quot;225&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;br /&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument :&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse à secteur magnétique isoprime (Elementar&lt;sup&gt;®&lt;/sup&gt;) couplé à un analyseur élémentaire vario MICRO cube (Elementar&lt;sup&gt;®&lt;/sup&gt;).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les échantillons solides (qui ont été pesés dans des capsules en étain) subissent une combustion à env. 1000°C. Ils sont convertis en CO&lt;sub&gt;2&lt;/sub&gt; gazeux. Le gaz échantillon est ensuite introduit dans la source du spectromètre sous flux d’hélium et est analysé par rapport à un gaz CO&lt;sub&gt;2&lt;/sub&gt; standard commercial.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les molécules du gaz sont ionisées dans la source, accélérées par un champ électrique et déviées en fonction de leur masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 44, 45 et 46. La précision de l’analyse de δ&lt;sup&gt;13&lt;/sup&gt;C est de 0.10‰.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Rapports des isotopes stables du carbone dans la cellulose et le bois&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Financements&amp;nbsp;:&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Projet &lt;strong&gt;:&lt;/strong&gt; RIOCAS, IDF-DIM-MAP-2021-3-001&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Monique Pierre : 01.69.08.31.20 / &lt;a href=&quot;mailto:monique.pierre@lsce.ipsl.fr&quot;&gt;monique.pierre[a]sce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Michel Stievenard : 01.69.08.71.70 / &lt;a href=&quot;mailto:michel.stievenard@lsce.ipsl.fr&quot;&gt;michel.stievenard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Vario MICRO cube - Isoprime, Elementar&lt;sup&gt;®&lt;/sup&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Photo1-ISOPRIME.png&quot; alt=&quot;Photo1 ISOPRIME&quot; width=&quot;300&quot; height=&quot;225&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;br /&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument :&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse à secteur magnétique isoprime (Elementar&lt;sup&gt;®&lt;/sup&gt;) couplé à un analyseur élémentaire vario MICRO cube (Elementar&lt;sup&gt;®&lt;/sup&gt;).&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les échantillons solides (qui ont été pesés dans des capsules en étain) subissent une combustion à env. 1000°C. Ils sont convertis en CO&lt;sub&gt;2&lt;/sub&gt; gazeux. Le gaz échantillon est ensuite introduit dans la source du spectromètre sous flux d’hélium et est analysé par rapport à un gaz CO&lt;sub&gt;2&lt;/sub&gt; standard commercial.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Les molécules du gaz sont ionisées dans la source, accélérées par un champ électrique et déviées en fonction de leur masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 44, 45 et 46. La précision de l’analyse de δ&lt;sup&gt;13&lt;/sup&gt;C est de 0.10‰.&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Rapports des isotopes stables du carbone dans la cellulose et le bois&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Financements&amp;nbsp;:&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Projet &lt;strong&gt;:&lt;/strong&gt; RIOCAS, IDF-DIM-MAP-2021-3-001&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Monique Pierre : 01.69.08.31.20 / &lt;a href=&quot;mailto:monique.pierre@lsce.ipsl.fr&quot;&gt;monique.pierre[a]sce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Michel Stievenard : 01.69.08.71.70 / &lt;a href=&quot;mailto:michel.stievenard@lsce.ipsl.fr&quot;&gt;michel.stievenard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="δ13C dans la cellulose et le bois" />
	</entry>
	<entry>
		<title>Mesure du δ18O de l’eau et de la glace</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/16-fiche-2-mesure-du-d18o-de-l-eau-et-de-la-glace"/>
		<published>2015-06-08T11:47:41+00:00</published>
		<updated>2015-06-08T11:47:41+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/16-fiche-2-mesure-du-d18o-de-l-eau-et-de-la-glace</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;p style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectromètre de masse à secteur magnétique Finnigan MAT252, couplé à un banc d’équilibration&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche2.png&quot; alt=&quot;fiche2&quot; width=&quot;267&quot; height=&quot;200&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Les échantillons d’eau (3mL) sont équilibrés pendant 8 heures avec du CO&lt;sub&gt;2&lt;/sub&gt;. Ce gaz est ensuite introduit dans le spectromètre de masse en mode de double injection.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Les mesures des échantillons se font par rapport à nos standards pendant 15 minutes.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Le principe du spectromètre de masse est basé sur l’ionisation dans la source, l’accélération par un champ électrique et la déviation en fonction de la masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 44, 45 et 46.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;a href=&quot;http://www.thermo.com.cn/Resources/200802/File_28763.pdf&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;http://www.thermo.com.cn/Resources/200802/File_28763.pdf&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses pouvant être faites sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’appareil est dédié à des analyses en routine de la composition isotopique en oxygène (&lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;O) des eaux naturelles. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Précision fournie par le laboratoire&amp;nbsp;: 2&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.05‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Bénédicte Minster (&lt;a href=&quot;https://www.lsce.ipsl.fr/Phocea/Vie_des_labos/Ast/ast_groupe.php?id_groupe=4&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;équipe GLACCIOS au LSCE&lt;/a&gt;)&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/Qbm-_vkRuTc&quot; width=&quot;560&quot; height=&quot;315&quot; allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen=&quot;&quot; frameborder=&quot;0&quot;&gt;&lt;/iframe&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;p style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectromètre de masse à secteur magnétique Finnigan MAT252, couplé à un banc d’équilibration&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche2.png&quot; alt=&quot;fiche2&quot; width=&quot;267&quot; height=&quot;200&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Les échantillons d’eau (3mL) sont équilibrés pendant 8 heures avec du CO&lt;sub&gt;2&lt;/sub&gt;. Ce gaz est ensuite introduit dans le spectromètre de masse en mode de double injection.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Les mesures des échantillons se font par rapport à nos standards pendant 15 minutes.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Le principe du spectromètre de masse est basé sur l’ionisation dans la source, l’accélération par un champ électrique et la déviation en fonction de la masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 44, 45 et 46.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;a href=&quot;http://www.thermo.com.cn/Resources/200802/File_28763.pdf&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;http://www.thermo.com.cn/Resources/200802/File_28763.pdf&lt;/span&gt;&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses pouvant être faites sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’appareil est dédié à des analyses en routine de la composition isotopique en oxygène (&lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;O) des eaux naturelles. &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Précision fournie par le laboratoire&amp;nbsp;: 2&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.05‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Bénédicte Minster (&lt;a href=&quot;https://www.lsce.ipsl.fr/Phocea/Vie_des_labos/Ast/ast_groupe.php?id_groupe=4&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;équipe GLACCIOS au LSCE&lt;/a&gt;)&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/Qbm-_vkRuTc&quot; width=&quot;560&quot; height=&quot;315&quot; allow=&quot;accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture&quot; allowfullscreen=&quot;&quot; frameborder=&quot;0&quot;&gt;&lt;/iframe&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="Mesure du δ18O de l’eau et de la glace" />
	</entry>
	<entry>
		<title>Mesure du δ18O et δ2H des eaux naturelles</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/17-fiche-3-mesure-du-d18o-et-dd-des-eaux-naturelles"/>
		<published>2015-07-27T12:04:28+00:00</published>
		<updated>2015-07-27T12:04:28+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/17-fiche-3-mesure-du-d18o-et-dd-des-eaux-naturelles</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Analyseur laser pour les isotopes de l’eau Picarro (L2130-i)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche3.png&quot; alt=&quot;&quot; width=&quot;321&quot; height=&quot;240&quot; /&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;16&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;18&lt;/sup&gt;O et HD&lt;sup&gt;16&lt;/sup&gt;O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;a href=&quot;https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses pouvant être faites sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;L’appareil L2120-i est dédié à des analyses en routine de la composition isotopique en oxygène (&lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O) et hydrogène (&lt;/span&gt;&lt;/span&gt;δ&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;D) des eaux naturelles. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Précisions fournies par le laboratoire&amp;nbsp;: 1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.2‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.7‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;D&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Bénédicte Minster&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Analyseur laser pour les isotopes de l’eau Picarro (L2130-i)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche3.png&quot; alt=&quot;&quot; width=&quot;321&quot; height=&quot;240&quot; /&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;16&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;18&lt;/sup&gt;O et HD&lt;sup&gt;16&lt;/sup&gt;O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;a href=&quot;https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses pouvant être faites sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;L’appareil L2120-i est dédié à des analyses en routine de la composition isotopique en oxygène (&lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O) et hydrogène (&lt;/span&gt;&lt;/span&gt;δ&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;D) des eaux naturelles. &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Précisions fournies par le laboratoire&amp;nbsp;: 1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.2‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt; = 0.7‰ pour le &lt;/span&gt;&lt;/span&gt;δ&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;D&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Bénédicte Minster&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="Mesure du δ18O et δ2H des eaux naturelles" />
	</entry>
	<entry>
		<title>Analyses du δ17O, δ18O et δ2H de l’eau et de la glace</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/18-fiche-4-analyses-du-d17o-d18o-et-dd-de-l-eau-et-de-la-glace"/>
		<published>2015-07-27T12:58:22+00:00</published>
		<updated>2015-07-27T12:58:22+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/18-fiche-4-analyses-du-d17o-d18o-et-dd-de-l-eau-et-de-la-glace</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Analyseur laser pour les isotopes de l’eau incluant &lt;sup&gt;17&lt;/sup&gt;O-excess Picarro (L2140-i)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche4.png&quot; alt=&quot;&quot; width=&quot;419&quot; height=&quot;315&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;16&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;18&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;17&lt;/sup&gt;O et HD&lt;sup&gt;16&lt;/sup&gt;O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes pour les rapports&lt;/span&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H et &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O et plusieurs heures pour l’analyse combinée &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;17&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O – &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;a href=&quot;https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor&quot;&gt;https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’appareil L2140-i est dédié à des analyses en routine de la composition isotopique en oxygène&lt;/span&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a; font-size: 12pt;&quot;&gt; (&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O, &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;17&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;O) et hydrogène (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H) des eaux naturelles.&lt;/span&gt; &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;Précisions fournies par le laboratoire&amp;nbsp;: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 0.2‰ pour le &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 0.7‰ pour le &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 10 ppm pour le &lt;sup&gt;17&lt;/sup&gt;O-excess&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Frédéric Prié : &lt;a href=&quot;mailto:frederic.prie@lsce.ipsl.fr&quot;&gt;frederic.prie[a]lsce.ipsl.fr&lt;/a&gt; &lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Analyseur laser pour les isotopes de l’eau incluant &lt;sup&gt;17&lt;/sup&gt;O-excess Picarro (L2140-i)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/fiche4.png&quot; alt=&quot;&quot; width=&quot;419&quot; height=&quot;315&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;16&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;18&lt;/sup&gt;O, H&lt;sub&gt;2&lt;/sub&gt;&lt;sup&gt;17&lt;/sup&gt;O et HD&lt;sup&gt;16&lt;/sup&gt;O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes pour les rapports&lt;/span&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H et &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O et plusieurs heures pour l’analyse combinée &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;17&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O – &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;a href=&quot;https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor&quot;&gt;https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’appareil L2140-i est dédié à des analyses en routine de la composition isotopique en oxygène&lt;/span&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a; font-size: 12pt;&quot;&gt; (&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O, &lt;/span&gt;&lt;/span&gt;δ&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;17&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;O) et hydrogène (&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H) des eaux naturelles.&lt;/span&gt; &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;Précisions fournies par le laboratoire&amp;nbsp;: &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 0.2‰ pour le &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;/span&gt;&lt;/span&gt;&lt;sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;18&lt;/span&gt;&lt;/span&gt;&lt;/sup&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;O&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 0.7‰ pour le &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;δ&lt;sup&gt;2&lt;/sup&gt;H&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt;1&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Symbol;&quot;&gt;&lt;span style=&quot;font-family: Symbol; color: #1a1a1a;&quot;&gt;s&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial', 'sans-serif'; color: #1a1a1a;&quot;&gt; = 10 ppm pour le &lt;sup&gt;17&lt;/sup&gt;O-excess&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Frédéric Prié : &lt;a href=&quot;mailto:frederic.prie@lsce.ipsl.fr&quot;&gt;frederic.prie[a]lsce.ipsl.fr&lt;/a&gt; &lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="Analyses du δ17O, δ18O et δ2H de l’eau et de la glace" />
	</entry>
	<entry>
		<title>Analyses du δ18O et δ13C dans des carbonates (15-50 microgrammes)</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/28-fiche-15-analyses-du-d18o-et-d13c-dans-des-carbonates"/>
		<published>2015-10-27T08:13:44+00:00</published>
		<updated>2015-10-27T08:13:44+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/28-fiche-15-analyses-du-d18o-et-d13c-dans-des-carbonates</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectromètre de masse IRMS ISOPRIME 100&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Isoprime_100_20210827_120613-reduit.jpg&quot; alt=&quot;figure14&quot; width=&quot;500&quot; height=&quot;375&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Spectromètre de masse IRMS ISOPRIME 100 est couplé à une ligne d’extraction. L’ensemble a été mis en service en 2014. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates, et en particulier les foraminifères benthiques et planctoniques. Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 15-200 microgrammes. La spécificité de ce spectromètre est la possibilité de mesurer un seul foraminifère (15 microgrammes).&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;D. Blamart : &lt;a href=&quot;mailto:dominique.blamart@lsce.ipsl.fr&quot;&gt;dominique.blamart[a]lsce.ipsl.fr&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;P. Richard : &lt;a href=&quot;mailto:patricia.richard@lsce.ipsl.fr&quot;&gt;patricia.richard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectromètre de masse IRMS ISOPRIME 100&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Isoprime_100_20210827_120613-reduit.jpg&quot; alt=&quot;figure14&quot; width=&quot;500&quot; height=&quot;375&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Spectromètre de masse IRMS ISOPRIME 100 est couplé à une ligne d’extraction. L’ensemble a été mis en service en 2014. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates, et en particulier les foraminifères benthiques et planctoniques. Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 15-200 microgrammes. La spécificité de ce spectromètre est la possibilité de mesurer un seul foraminifère (15 microgrammes).&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;D. Blamart : &lt;a href=&quot;mailto:dominique.blamart@lsce.ipsl.fr&quot;&gt;dominique.blamart[a]lsce.ipsl.fr&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;P. Richard : &lt;a href=&quot;mailto:patricia.richard@lsce.ipsl.fr&quot;&gt;patricia.richard[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;</content>
		<category term="Analyses du δ18O et δ13C dans des carbonates (15-50 microgrammes)" />
	</entry>
	<entry>
		<title>Analyses du δ18O et δ13C dans des carbonates </title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/29-fiche-16-analyses-du-d18o-et-d13c-dans-des-carbonates"/>
		<published>2015-10-27T08:37:52+00:00</published>
		<updated>2015-10-27T08:37:52+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/29-fiche-16-analyses-du-d18o-et-d13c-dans-des-carbonates</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectrometre de masse IRMS GV ISOPRIME&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Isoprime_GV_20210827_120613-reduit.jpg&quot; alt=&quot;figure15&quot; width=&quot;500&quot; height=&quot;375&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse IRMS GV ISOPRIME couplé à une ligne d’extraction. Il a été mis en service en 2006. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates : foraminifères bentiques et planctoniques, poudre de carbonates (spéléothèmes par exemple)... Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 40-100 microgrammes.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;D. Blamart : &lt;a href=&quot;mailto:dominique.blamart@lsce.ipsl.fr&quot;&gt;dominique.blamart[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;P. Richard : &lt;a href=&quot;mailto:patricia.richard@lsce.ipsl.fr&quot;&gt;patricia.richard[a]lsce.ipsl.fr&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;</summary>
		<content type="html">&lt;p style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif'; font-weight: bold;&quot;&gt;Spectrometre de masse IRMS GV ISOPRIME&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/Isoprime_GV_20210827_120613-reduit.jpg&quot; alt=&quot;figure15&quot; width=&quot;500&quot; height=&quot;375&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;&quot;&gt;Spectromètre de masse IRMS GV ISOPRIME couplé à une ligne d’extraction. Il a été mis en service en 2006. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates : foraminifères bentiques et planctoniques, poudre de carbonates (spéléothèmes par exemple)... Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 40-100 microgrammes.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;D. Blamart : &lt;a href=&quot;mailto:dominique.blamart@lsce.ipsl.fr&quot;&gt;dominique.blamart[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;P. Richard : &lt;a href=&quot;mailto:patricia.richard@lsce.ipsl.fr&quot;&gt;patricia.richard[a]lsce.ipsl.fr&lt;/a&gt;&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;</content>
		<category term="Analyses du δ18O et δ13C dans des carbonates " />
	</entry>
	<entry>
		<title>Analyses des éléments majeurs et traces dans différentes matrices (eaux, sédiments, roches et carbonates) et datations U/Th (carbonates) par ICP-QMS</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/38-fiche-25-analyses-des-elements-majeurs-et-traces-dans-differentes-matrice-eaux-sediments-et-roches-et-datations-u-th-carbonates"/>
		<published>2015-12-07T08:50:24+00:00</published>
		<updated>2015-12-07T08:50:24+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/38-fiche-25-analyses-des-elements-majeurs-et-traces-dans-differentes-matrice-eaux-sediments-et-roches-et-datations-u-th-carbonates</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Spectromètre de masse à source «&amp;nbsp;plasma&amp;nbsp;» quadrupolaire - ICP-QMS X-series&lt;sup&gt;II&lt;/sup&gt; CCT&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/ICP-TQMS.jpg&quot; alt=&quot;ICP TQMS&quot; width=&quot;449&quot; height=&quot;279&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif'; font-weight: bold;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif';&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Le spectromètre de masse quadrupolaire à source «&amp;nbsp;Plasma d’argon&amp;nbsp;» (ICP-QMS) X-series&lt;sup&gt;II&lt;/sup&gt; CCT&lt;em&gt;&lt;sup&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;Thermo Fisher Scientific &lt;/span&gt;&lt;/sup&gt;&lt;/em&gt;est dédié à l’analyse quantitative multi-élémentaire. Cet instrument permet la quantification rapide (quelques minutes), précise (~ pourcent) et quasi-simultanée de la teneur de nombreux éléments chimiques du Tableau Périodique allant des éléments majeurs à ceux présents à l’état de traces dans des échantillons naturels (eaux douces, eau de mer, végétaux, sols, carbonates, apatites, roches, etc.) ou dans tout autre type de matériaux ou solutions. Dans sa configuration de base, ce spectromètre permet d’atteindre des limites de détection inférieures au µg/L (ppb) voire quelques centaines de pg/L (ppq) pour les éléments lourds tels que les terres rares ou l’uranium. Deux options permettent d’améliorer ses performances&amp;nbsp;: &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;i-&lt;/span&gt;&lt;/em&gt; la cellule à collision CCT élimine les interférences gênantes, en particulier pour l’analyse des éléments dont la masse atomique se situe entre 40 et 80 (métaux de transition, métalloïdes type As, Se)&amp;nbsp;; &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;ii-&lt;/span&gt;&lt;/em&gt; une option S de pompage additionnel à l’interface peut abaisser à quelques pg/L la limite de détection de certains éléments lourds (uranium). &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Trois grandes domaines d’applications sont aujourd’hui développer au LSCE: &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;i-&lt;/span&gt;&lt;/em&gt; la caractérisation élémentaire ou isotopique (Pb) d’échantillons mis en solution pour le traçage des processus d’érosion des bassins versants, l’étude de la mobilité de particules ainsi que la détermination de leurs origines, et le suivi quantitatif du devenir de certains métaux lourds ou toxiques dans l’environnement, en particulier en environnement urbain&amp;nbsp;; &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;ii- &lt;/span&gt;&lt;/em&gt;la caractérisation élémentaire des carbonates/apatites marins (coraux, foraminifères) ou continentaux (spéléothèmes, dents, etc.) pour des études en paléo- océanographie ou climatologie (température des masses d’eau, géochimie des masses d’eau, cycle du carbone, précipitations, etc.) et &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;iii-&lt;/span&gt;&lt;/em&gt; la géochronologie et la datation U-Th des carbonates ou apatites.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif';&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif';&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Le principe est basé sur la dissociation des molécules, l’atomisation et l’ionisation des éléments présents dans une solution dans une source «&amp;nbsp;Plasma&amp;nbsp;» d’argon à 6000-8000°K sous pression atmosphérique. Après formation d’un faisceau d’ions via l’interface (cônes échantillonneur puis écrêteur) et le passage progressif vers un espace sous vide secondaire, la séparation (&amp;lt; 0,7 uma) des ions et des isotopes se fait à basse résolution selon leur rapport masse sur charge (m/z) par un Quadrupole. Les ions sont alors détectés par un multiplieur d’électrons à dynode discrète. La quantification des teneurs en éléments majeurs et/ou traces est obtenue après étalonnage de l’instrumentation (solutions standards connus ou certifiées). Selon la matrice ou la nature des échantillons analysés, les éléments étudiés et le degré de précision recherché, différentes méthodes d’étalonnage sont mises en œuvre (courbes d’étalonnage standard, méthode dérivée des ajouts-dosés, méthode dite d’encadrement).&lt;/span&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif'; font-weight: bold; font-style: italic;&quot;&gt;Autres particularités de l’ICP-QMS au LSCE&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Nébuliseurs utilisés type PFA 20, 50 ou 100 µL/min ou quartz 1 mL/mn (solutions);&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Chambres en quartz micro-cyclonique&amp;nbsp;ou à bille d’impact (solutions);&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Système de dé-solvatation APEX OMEGA disponible (gain en sensibilité X 2 à 10, solutions)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Système d’ablation laser New Wave ESI - 193 nm potentiellement couplé (mesures &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;in-situ&lt;/span&gt;&lt;/em&gt;, solides).&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des éléments majeurs et traces présents dans les eaux, sols, roches, carbonates (érosion/transfert de particules)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Mesure relative des isotopes du Pb (traçage de sources) ;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des éléments majeurs (Sr/Ca, Mg/Ca) et traces (Li/Mg&amp;nbsp;; B/Ca&amp;nbsp;; U/Ca, REE, etc.) présents dans carbonates/apatites (paléoocéanographie/climatologie/cycle du carbone)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des terres rares et autres éléments présents comme ultra-traces (caractérisation des matériaux ou de processus)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Mesure relative des isotopes de l’U et du Th pour la datation U-Th et ses extensions U-Th-ESR ou U-Th-He.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Delphine Thomas : &lt;a href=&quot;mailto:delphine.thomas@lsce.ipsl.fr&quot;&gt;delphine.thomas[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Louise.Bordier@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; 01 69 08 33 77&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Sophie Ayrault : &lt;a href=&quot;mailto:sophie.ayrault@lsce.ipsl.fr&quot;&gt;sophie.ayrault[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Sophie.Ayrault@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp; 01 69 08 40 71&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Eric Douville : &lt;a href=&quot;mailto:eric.douville@lsce.ipsl.fr&quot;&gt;eric.douville[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Eric.Douville@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 01 69 08 22 57&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Spectromètre de masse à source «&amp;nbsp;plasma&amp;nbsp;» quadrupolaire - ICP-QMS X-series&lt;sup&gt;II&lt;/sup&gt; CCT&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/ICP-TQMS.jpg&quot; alt=&quot;ICP TQMS&quot; width=&quot;449&quot; height=&quot;279&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif'; font-weight: bold;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri', 'sans-serif';&quot;&gt; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Le spectromètre de masse quadrupolaire à source «&amp;nbsp;Plasma d’argon&amp;nbsp;» (ICP-QMS) X-series&lt;sup&gt;II&lt;/sup&gt; CCT&lt;em&gt;&lt;sup&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;Thermo Fisher Scientific &lt;/span&gt;&lt;/sup&gt;&lt;/em&gt;est dédié à l’analyse quantitative multi-élémentaire. Cet instrument permet la quantification rapide (quelques minutes), précise (~ pourcent) et quasi-simultanée de la teneur de nombreux éléments chimiques du Tableau Périodique allant des éléments majeurs à ceux présents à l’état de traces dans des échantillons naturels (eaux douces, eau de mer, végétaux, sols, carbonates, apatites, roches, etc.) ou dans tout autre type de matériaux ou solutions. Dans sa configuration de base, ce spectromètre permet d’atteindre des limites de détection inférieures au µg/L (ppb) voire quelques centaines de pg/L (ppq) pour les éléments lourds tels que les terres rares ou l’uranium. Deux options permettent d’améliorer ses performances&amp;nbsp;: &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;i-&lt;/span&gt;&lt;/em&gt; la cellule à collision CCT élimine les interférences gênantes, en particulier pour l’analyse des éléments dont la masse atomique se situe entre 40 et 80 (métaux de transition, métalloïdes type As, Se)&amp;nbsp;; &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;ii-&lt;/span&gt;&lt;/em&gt; une option S de pompage additionnel à l’interface peut abaisser à quelques pg/L la limite de détection de certains éléments lourds (uranium). &lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; Trois grandes domaines d’applications sont aujourd’hui développer au LSCE: &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;i-&lt;/span&gt;&lt;/em&gt; la caractérisation élémentaire ou isotopique (Pb) d’échantillons mis en solution pour le traçage des processus d’érosion des bassins versants, l’étude de la mobilité de particules ainsi que la détermination de leurs origines, et le suivi quantitatif du devenir de certains métaux lourds ou toxiques dans l’environnement, en particulier en environnement urbain&amp;nbsp;; &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;ii- &lt;/span&gt;&lt;/em&gt;la caractérisation élémentaire des carbonates/apatites marins (coraux, foraminifères) ou continentaux (spéléothèmes, dents, etc.) pour des études en paléo- océanographie ou climatologie (température des masses d’eau, géochimie des masses d’eau, cycle du carbone, précipitations, etc.) et &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;iii-&lt;/span&gt;&lt;/em&gt; la géochronologie et la datation U-Th des carbonates ou apatites.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif';&quot;&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif';&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif;&quot;&gt;Le principe est basé sur la dissociation des molécules, l’atomisation et l’ionisation des éléments présents dans une solution dans une source «&amp;nbsp;Plasma&amp;nbsp;» d’argon à 6000-8000°K sous pression atmosphérique. Après formation d’un faisceau d’ions via l’interface (cônes échantillonneur puis écrêteur) et le passage progressif vers un espace sous vide secondaire, la séparation (&amp;lt; 0,7 uma) des ions et des isotopes se fait à basse résolution selon leur rapport masse sur charge (m/z) par un Quadrupole. Les ions sont alors détectés par un multiplieur d’électrons à dynode discrète. La quantification des teneurs en éléments majeurs et/ou traces est obtenue après étalonnage de l’instrumentation (solutions standards connus ou certifiées). Selon la matrice ou la nature des échantillons analysés, les éléments étudiés et le degré de précision recherché, différentes méthodes d’étalonnage sont mises en œuvre (courbes d’étalonnage standard, méthode dérivée des ajouts-dosés, méthode dite d’encadrement).&lt;/span&gt; &lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family: Calibri;&quot;&gt;&lt;span style=&quot;font-family: 'Calibri','sans-serif'; font-weight: bold; font-style: italic;&quot;&gt;Autres particularités de l’ICP-QMS au LSCE&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/p&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Nébuliseurs utilisés type PFA 20, 50 ou 100 µL/min ou quartz 1 mL/mn (solutions);&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Chambres en quartz micro-cyclonique&amp;nbsp;ou à bille d’impact (solutions);&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Système de dé-solvatation APEX OMEGA disponible (gain en sensibilité X 2 à 10, solutions)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Système d’ablation laser New Wave ESI - 193 nm potentiellement couplé (mesures &lt;em&gt;&lt;span style=&quot;font-style: italic;&quot;&gt;in-situ&lt;/span&gt;&lt;/em&gt;, solides).&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des éléments majeurs et traces présents dans les eaux, sols, roches, carbonates (érosion/transfert de particules)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Mesure relative des isotopes du Pb (traçage de sources) ;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des éléments majeurs (Sr/Ca, Mg/Ca) et traces (Li/Mg&amp;nbsp;; B/Ca&amp;nbsp;; U/Ca, REE, etc.) présents dans carbonates/apatites (paléoocéanographie/climatologie/cycle du carbone)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Quantification des terres rares et autres éléments présents comme ultra-traces (caractérisation des matériaux ou de processus)&amp;nbsp;;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span style=&quot;font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;font-style: normal; font-weight: normal; line-height: normal; font-size-adjust: none; font-stretch: normal; font-feature-settings: normal; font-language-override: normal; font-kerning: auto; font-synthesis: weight style; font-variant: normal;&quot;&gt;&lt;/span&gt;Mesure relative des isotopes de l’U et du Th pour la datation U-Th et ses extensions U-Th-ESR ou U-Th-He.&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial;&quot;&gt;&lt;span style=&quot;font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Delphine Thomas : &lt;a href=&quot;mailto:delphine.thomas@lsce.ipsl.fr&quot;&gt;delphine.thomas[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Louise.Bordier@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; 01 69 08 33 77&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Sophie Ayrault : &lt;a href=&quot;mailto:sophie.ayrault@lsce.ipsl.fr&quot;&gt;sophie.ayrault[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Sophie.Ayrault@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp; 01 69 08 40 71&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Eric Douville : &lt;a href=&quot;mailto:eric.douville@lsce.ipsl.fr&quot;&gt;eric.douville[a]lsce.ipsl.fr&lt;/a&gt;&lt;a href=&quot;mailto:Eric.Douville@lsce.ipsl.xn--fr-qia&quot;&gt;&lt;/a&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; 01 69 08 22 57&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;</content>
		<category term="Analyses des éléments majeurs et traces dans différentes matrices (eaux, sédiments, roches et carbonates) et datations U/Th (carbonates) par ICP-QMS" />
	</entry>
	<entry>
		<title>Analyses des propriétés magnétiques et magnétostratigraphie sur séries continues (NRM et ARM)</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/42-fiche-30-analyses-des-proprietes-magnetiques-et-magnetostratigraphie-mrm-et-arm"/>
		<published>2015-12-07T09:07:04+00:00</published>
		<updated>2015-12-07T09:07:04+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/42-fiche-30-analyses-des-proprietes-magnetiques-et-magnetostratigraphie-mrm-et-arm</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Magnétomètre cryogénique haute résolution pour séries continues sans hélium (2G Enterprises)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/photo_cryosanshelium.png&quot; alt=&quot;photo cryosanshelium&quot; width=&quot;600&quot; height=&quot;291&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Magnétomètre cryogénique dédié à la mesure de séries continues car équipé de capteurs tri-axiaux haute résolution (4.5 cm). Ces séries continues doivent avoir une section carrée de max 22 mm et une longueur de maximum 1.5 m (typiquement u-channels). Il est installé en ligne avec des bobines de désaimantation par champs alternatifs et solénoïde. Magnétomètre placé dans la chambre amagnétique.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’instrument est un magnétomètre à bas bruit de fond mesurant en une fois les trois composantes dans l’espace de l’aimantation rémanente contenue dans l’échantillon. Cette aimantation peut être l’aimantation rémanente naturelle et l’aimantation rémanente anhystérétique (acquise par application «&amp;nbsp;en ligne&amp;nbsp;» de champ alternatif et de champ continu). Ces aimantations peuvent être désaimantées sur les trois axes de l’espace par champ alternatif (jusqu’à 80 mT) grâce aux bobines montées également en ligne. Ce magnétomètre est dédié aux mesures de séries continues car équipé de capteurs haute résolution. Les données sont sauvegardées sous forme de fichier texte en X, Y, Z, déclinaison, inclinaison et intensité.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Aimantation rémanente naturelle (NRM)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Aimantation rémanente anhystérétique (ARM)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Sur sédiments (u-channels) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Gwenaël Hervé :&amp;nbsp;01.69.08.02.48 /&amp;nbsp;&lt;a href=&quot;mailto:gwenael.herve@lsce.ipsl.fr&quot;&gt;gwenael.herve[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Magnétomètre cryogénique haute résolution pour séries continues sans hélium (2G Enterprises)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&amp;nbsp;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/photo_cryosanshelium.png&quot; alt=&quot;photo cryosanshelium&quot; width=&quot;600&quot; height=&quot;291&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Magnétomètre cryogénique dédié à la mesure de séries continues car équipé de capteurs tri-axiaux haute résolution (4.5 cm). Ces séries continues doivent avoir une section carrée de max 22 mm et une longueur de maximum 1.5 m (typiquement u-channels). Il est installé en ligne avec des bobines de désaimantation par champs alternatifs et solénoïde. Magnétomètre placé dans la chambre amagnétique.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;L’instrument est un magnétomètre à bas bruit de fond mesurant en une fois les trois composantes dans l’espace de l’aimantation rémanente contenue dans l’échantillon. Cette aimantation peut être l’aimantation rémanente naturelle et l’aimantation rémanente anhystérétique (acquise par application «&amp;nbsp;en ligne&amp;nbsp;» de champ alternatif et de champ continu). Ces aimantations peuvent être désaimantées sur les trois axes de l’espace par champ alternatif (jusqu’à 80 mT) grâce aux bobines montées également en ligne. Ce magnétomètre est dédié aux mesures de séries continues car équipé de capteurs haute résolution. Les données sont sauvegardées sous forme de fichier texte en X, Y, Z, déclinaison, inclinaison et intensité.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Aimantation rémanente naturelle (NRM)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Aimantation rémanente anhystérétique (ARM)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;&quot;&gt;Sur sédiments (u-channels) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a; font-family: Arial; font-size: small;&quot;&gt;&lt;span style=&quot;font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Gwenaël Hervé :&amp;nbsp;01.69.08.02.48 /&amp;nbsp;&lt;a href=&quot;mailto:gwenael.herve@lsce.ipsl.fr&quot;&gt;gwenael.herve[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</content>
		<category term="Analyses des propriétés magnétiques et magnétostratigraphie sur séries continues (NRM et ARM)" />
	</entry>
	<entry>
		<title>Analyses des propriétés magnétiques et magnétostratigraphie sur séries continues (IRM et S-ratio)</title>
		<link rel="alternate" type="text/html" href="https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/43-fiche-31-analyses-des-proprietes-magnetiques-et-magnetostratigraphie-irm-et-s-ratio"/>
		<published>2015-12-07T09:19:17+00:00</published>
		<updated>2015-12-07T09:19:17+00:00</updated>
		<id>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/43-fiche-31-analyses-des-proprietes-magnetiques-et-magnetostratigraphie-irm-et-s-ratio</id>
		<author>
			<name>Super User</name>
		</author>
		<summary type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Magnétomètre cryogénique haute résolution pour séries continues avec hélium (2G Enterprises)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/photo_cryoIRM.png&quot; alt=&quot;photo cryoIRM&quot; width=&quot;308&quot; height=&quot;230&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Magnétomètre cryogénique dédié à la mesure de séries continues car équipé de capteurs tri-axiaux haute résolution (4.5 cm). Ces séries continues doivent avoir une section carrée de max 22 mm et une longueur de maximum 1.5 m (typiquement u-channels). Ce magnétomètre est installé en ligne avec des bobines de désaimantation par champs alternatifs et un long solénoïde. Magnétomètres placés dans la chambre amagnétique.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;L’instrument est un magnétomètre à bas bruit de fond mesurant en une fois les trois composantes dans l’espace de l’aimantation rémanente contenue dans l’échantillon. Cette aimantation est l’aimantation rémanente isotherme acquise en ligne par application d’un champ continu fort (jusqu’à 1T). Elle peut ensuite être désaimantée sur les trois axes de l’espace par champ alternatif (jusqu’à 80 mT) grâce aux bobines montées également en ligne. Ce magnétomètre est dédié aux mesures de séries continues car équipé de capteurs haute résolution. Les données sont sauvegardées sous forme de fichier texte en X, Y, Z, déclinaison, inclinaison et intensité.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Aimantation rémanente isotherme (IRM, S-ratio)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Sur sédiments (u-channels) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Gwenaël Hervé :&amp;nbsp;01.69.08.02.48 /&amp;nbsp;&lt;a href=&quot;mailto:gwenael.herve@lsce.ipsl.fr&quot;&gt;gwenael.herve[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</summary>
		<content type="html">&lt;h2 style=&quot;margin-bottom: 12pt; text-align: center;&quot;&gt;&lt;span style=&quot;font-size: 14pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;font-weight: bold;&quot;&gt;Magnétomètre cryogénique haute résolution pour séries continues avec hélium (2G Enterprises)&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h2&gt;
&lt;p&gt;&lt;img src=&quot;https://panoply-geops.lsce.ipsl.fr/images/photo_cryoIRM.png&quot; alt=&quot;photo cryoIRM&quot; width=&quot;308&quot; height=&quot;230&quot; style=&quot;display: block; margin-left: auto; margin-right: auto;&quot; /&gt;&lt;/p&gt;
&lt;p&gt;&amp;nbsp;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Description de l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Magnétomètre cryogénique dédié à la mesure de séries continues car équipé de capteurs tri-axiaux haute résolution (4.5 cm). Ces séries continues doivent avoir une section carrée de max 22 mm et une longueur de maximum 1.5 m (typiquement u-channels). Ce magnétomètre est installé en ligne avec des bobines de désaimantation par champs alternatifs et un long solénoïde. Magnétomètres placés dans la chambre amagnétique.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Principe de l’analyse&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;L’instrument est un magnétomètre à bas bruit de fond mesurant en une fois les trois composantes dans l’espace de l’aimantation rémanente contenue dans l’échantillon. Cette aimantation est l’aimantation rémanente isotherme acquise en ligne par application d’un champ continu fort (jusqu’à 1T). Elle peut ensuite être désaimantée sur les trois axes de l’espace par champ alternatif (jusqu’à 80 mT) grâce aux bobines montées également en ligne. Ce magnétomètre est dédié aux mesures de séries continues car équipé de capteurs haute résolution. Les données sont sauvegardées sous forme de fichier texte en X, Y, Z, déclinaison, inclinaison et intensité.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Analyses réalisées sur l’instrument&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;ul&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Aimantation rémanente isotherme (IRM, S-ratio)&lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;&quot;&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;Sur sédiments (u-channels) &lt;/span&gt;&lt;/span&gt;&lt;/li&gt;
&lt;/ul&gt;
&lt;p style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h4 style=&quot;margin-bottom: 12pt;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;&lt;strong&gt;&lt;span style=&quot;color: #1a1a1a;&quot;&gt;&lt;span style=&quot;color: #1a1a1a; font-weight: bold;&quot;&gt;Contacts&amp;nbsp;:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;span style=&quot;font-family: arial, helvetica, sans-serif; font-size: 12pt;&quot;&gt;Gwenaël Hervé :&amp;nbsp;01.69.08.02.48 /&amp;nbsp;&lt;a href=&quot;mailto:gwenael.herve@lsce.ipsl.fr&quot;&gt;gwenael.herve[a]lsce.ipsl.fr&lt;/a&gt;&lt;/span&gt;&lt;span style=&quot;font-family: Cambria; font-size: small;&quot;&gt;&lt;/span&gt;&lt;span style=&quot;font-size: 12pt;&quot;&gt;&lt;br /&gt;&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;</content>
		<category term="Analyses des propriétés magnétiques et magnétostratigraphie sur séries continues (IRM et S-ratio)" />
	</entry>
</feed>
