<?xml version="1.0" encoding="utf-8"?>
<!-- generator="Joomla! - Open Source Content Management" -->
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom">
	<channel>
		<title>Panoply - T1.3 Datation des archives climatiques</title>
		<description><![CDATA[PANOPLY met à la disposition de la communauté scientifique académique et industrielle l'éventail des ressources de hautes technologies du Plateau de Saclay dans le domaine des sciences de la Terre, du Climat et de l’environnement.]]></description>
		<link>https://panoply-geops.lsce.ipsl.fr/index.php/thematiques-scientifiques/les-fiches-par-thematique/t1-geochronologie/t1-3-datation-des-archives-climatiques</link>
		<lastBuildDate>Fri, 19 Jun 2026 16:35:50 +0000</lastBuildDate>
		<generator>Joomla! - Open Source Content Management</generator>
		<atom:link rel="self" type="application/rss+xml" href="https://panoply-geops.lsce.ipsl.fr/index.php/thematiques-scientifiques/les-fiches-par-thematique/t1-geochronologie/t1-3-datation-des-archives-climatiques?format=feed&amp;type=rss"/>
		<language>fr-fr</language>
		<managingEditor>nada.caud@lsce.ipsl.fr (Panoply)</managingEditor>
		<item>
			<title>Mesure du δ18O de l’eau et de la glace</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/16-fiche-2-mesure-du-d18o-de-l-eau-et-de-la-glace</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/16-fiche-2-mesure-du-d18o-de-l-eau-et-de-la-glace</guid>
			<description><![CDATA[<p style="text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectromètre de masse à secteur magnétique Finnigan MAT252, couplé à un banc d’équilibration</span></span></strong></span></p>
<p style="text-align: center;">&nbsp;</p>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche2.png" alt="fiche2" width="267" height="200" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<p>&nbsp;</p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Les échantillons d’eau (3mL) sont équilibrés pendant 8 heures avec du CO<sub>2</sub>. Ce gaz est ensuite introduit dans le spectromètre de masse en mode de double injection.</span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Les mesures des échantillons se font par rapport à nos standards pendant 15 minutes.</span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Le principe du spectromètre de masse est basé sur l’ionisation dans la source, l’accélération par un champ électrique et la déviation en fonction de la masse par un champ magnétique. Trois cages de Faraday sont placées en sortie et permettent de récupérer les masses 44, 45 et 46.</span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></p>
<p style="margin-bottom: 12pt;"><span style="font-size: 12pt;"><a href="http://www.thermo.com.cn/Resources/200802/File_28763.pdf"><span style="color: #1a1a1a; font-family: Arial;">http://www.thermo.com.cn/Resources/200802/File_28763.pdf</span></a></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses pouvant être faites sur l’instrument&nbsp;:</span></span></strong></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">L’appareil est dédié à des analyses en routine de la composition isotopique en oxygène (</span></span>δ<sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;">O) des eaux naturelles. </span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Précision fournie par le laboratoire&nbsp;: 2</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 0.05‰ pour le </span></span>δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O</span></span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></p>
<p><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Bénédicte Minster (<a href="https://www.lsce.ipsl.fr/Phocea/Vie_des_labos/Ast/ast_groupe.php?id_groupe=4" target="_blank" rel="noopener">équipe GLACCIOS au LSCE</a>)<br /></span></span></p>
<p>&nbsp;</p>
<p><iframe src="https://www.youtube.com/embed/Qbm-_vkRuTc" width="560" height="315" allow="accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture" allowfullscreen="" frameborder="0"></iframe></p>
<p>&nbsp;</p>]]></description>
			<category>Mesure du δ18O de l’eau et de la glace</category>
			<pubDate>Mon, 08 Jun 2015 11:47:41 +0000</pubDate>
		</item>
		<item>
			<title>Mesure du δ18O et δ2H des eaux naturelles</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/17-fiche-3-mesure-du-d18o-et-dd-des-eaux-naturelles</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/17-fiche-3-mesure-du-d18o-et-dd-des-eaux-naturelles</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt; font-family: arial, helvetica, sans-serif;"><strong><span style="font-weight: bold;">Analyseur laser pour les isotopes de l’eau Picarro (L2130-i)</span></strong></span></h2>
<p style="margin-bottom: 12pt; text-align: center;">&nbsp;</p>
<p style="margin-bottom: 12pt; text-align: center;"><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche3.png" alt="" width="321" height="240" /></p>
<p style="margin-bottom: 12pt; text-align: center;">&nbsp;</p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;"><span style="color: #1a1a1a;">Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H<sub>2</sub><sup>16</sup>O, H<sub>2</sub><sup>18</sup>O et HD<sup>16</sup>O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes.</span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></span></p>
<p style="margin-bottom: 12pt;"><a href="https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer"><span style="color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;">https://www.picarro.com/products/l2130i_isotope_and_gas_concentration_analyzer</span></a></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Analyses pouvant être faites sur l’instrument&nbsp;:</span></span></strong></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">L’appareil L2120-i est dédié à des analyses en routine de la composition isotopique en oxygène (</span></span>δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O) et hydrogène (</span></span>δ<span style="color: #1a1a1a;"><span style="color: #1a1a1a;">D) des eaux naturelles. </span></span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Précisions fournies par le laboratoire&nbsp;: 1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 0.2‰ pour le </span></span>δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O</span></span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 0.7‰ pour le </span></span>δ<span style="color: #1a1a1a;"><span style="color: #1a1a1a;">D</span></span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></span></p>
<p><span style="color: #1a1a1a; font-size: 12pt; font-family: arial, helvetica, sans-serif;"><span style="color: #1a1a1a;">Bénédicte Minster<br /></span></span></p>
<p style="margin-bottom: 12pt;">&nbsp;</p>]]></description>
			<category>Mesure du δ18O et δ2H des eaux naturelles</category>
			<pubDate>Mon, 27 Jul 2015 12:04:28 +0000</pubDate>
		</item>
		<item>
			<title>Analyses du δ17O, δ18O et δ2H de l’eau et de la glace</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/18-fiche-4-analyses-du-d17o-d18o-et-dd-de-l-eau-et-de-la-glace</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/18-fiche-4-analyses-du-d17o-d18o-et-dd-de-l-eau-et-de-la-glace</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt; font-family: arial, helvetica, sans-serif;"><strong><span style="font-weight: bold;">Analyseur laser pour les isotopes de l’eau incluant <sup>17</sup>O-excess Picarro (L2140-i)</span></strong></span></h2>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche4.png" alt="" width="419" height="315" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Le principe de l’analyseur isotopique est basé sur le temps de décroissance d’un faisceau laser pour mesurer les caractéristiques spectrales des molécules H<sub>2</sub><sup>16</sup>O, H<sub>2</sub><sup>18</sup>O, H<sub>2</sub><sup>17</sup>O et HD<sup>16</sup>O en phase gazeuse dans une cavité optique. Les échantillons sont automatiquement injectés (2 microlitres) dans un module de vaporisation à 110 °C avant d’être envoyé dans la cavité laser. Le temps nécessaire à la mesure d’un échantillon est de 9 minutes pour les rapports</span><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;"> </span></span><span style="font-size: 12pt;"><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ<sup>2</sup>H et </span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ</span></span><sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">O et plusieurs heures pour l’analyse combinée </span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ</span></span><sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">17</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">O – </span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ</span></span><sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">O.</span></span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><a href="https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor">https://www.picarro.com/isotope_analyzers/h2o_isotopes_liquid_and_vapor</a></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">L’appareil L2140-i est dédié à des analyses en routine de la composition isotopique en oxygène</span><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a; font-size: 12pt;"> (</span></span><span style="font-size: 12pt;">δ<sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">O, </span></span>δ<sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">17</span></span></sup></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;"><span style="font-size: 12pt;">O) et hydrogène (</span></span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;"><span style="font-size: 12pt;">δ<sup>2</sup>H) des eaux naturelles.</span> </span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-size: 12pt;"><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">Précisions fournies par le laboratoire&nbsp;: </span></span></span></p>
<ul>
<li style="margin-bottom: 12pt;"><span style="font-size: 12pt;"><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">1</span></span><span style="color: #1a1a1a; font-family: Symbol;"><span style="font-family: Symbol; color: #1a1a1a;">s</span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;"> = 0.2‰ pour le </span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ</span></span><sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">O</span></span></span></li>
<li style="margin-bottom: 12pt;"><span style="font-size: 12pt;"><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">1</span></span><span style="color: #1a1a1a; font-family: Symbol;"><span style="font-family: Symbol; color: #1a1a1a;">s</span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;"> = 0.7‰ pour le </span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">δ<sup>2</sup>H</span></span></span></li>
<li style="margin-bottom: 12pt;"><span style="font-size: 12pt;"><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;">1</span></span><span style="color: #1a1a1a; font-family: Symbol;"><span style="font-family: Symbol; color: #1a1a1a;">s</span></span><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial', 'sans-serif'; color: #1a1a1a;"> = 10 ppm pour le <sup>17</sup>O-excess</span></span></span></li>
</ul>
<p style="margin-bottom: 12pt;">&nbsp;</p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></h4>
<p><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Frédéric Prié : <a href="mailto:frederic.prie@lsce.ipsl.fr">frederic.prie[a]lsce.ipsl.fr</a> <br /></span></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>]]></description>
			<category>Analyses du δ17O, δ18O et δ2H de l’eau et de la glace</category>
			<pubDate>Mon, 27 Jul 2015 12:58:22 +0000</pubDate>
		</item>
		<item>
			<title>Mesure du δ15N - N2, δ18O - O2, δ40Ar/36Ar, δ40Ar/38Ar et δ17O - O2 dans l’air (Delta V+)</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/19-fiche-5-mesure-du-d15n-n2-d18o-o2-d40ar-36ar-d40ar-38ar-et-d17o-o2-dans-l-air</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/19-fiche-5-mesure-du-d15n-n2-d18o-o2-d40ar-36ar-d40ar-38ar-et-d17o-o2-dans-l-air</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectromètre de masse à secteur magnétique Delta V+ / Possibilité de couplage avec lignes d’extraction, de purification et de fluorination</span></span></strong></span></h2>
<table style="margin-left: auto; margin-right: auto; width: 618px; height: 212px;">
<tbody>
<tr>
<td><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche5.png" alt="" width="266" height="199" /></td>
<td>&nbsp;</td>
<td><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche5_bis.png" alt="" width="268" height="200" /></td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Le principe du spectromètre de masse est basé sur l’ionisation dans la source, l’accélération par un champ électrique et la déviation en fonction de la masse par un champ magnétique. 10 cages de Faraday sont placées en sortie et permettent de récupérer les masses 28, 29, 30, 32, 33, 34, 36, 38, 40 et 44. Il est équipé d’un module de double injection.</span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Cet instrument peut être couplé à une ligne d’extraction des gaz de la glace, à différents systèmes de purification de l’air utilisant des colonnes chromatographiques ou des systèmes d’adsorption et à une ligne de fluorination de l’eau. A la sortie de ces différentes lignes de préparation, les échantillons d’air purifié sont piégés dans l’hélium liquide et connectés au spectromètre de masse.</span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><a href="http://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_26513.pdf"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt;">http://www.thermo.com/eThermo/CMA/PDFs/Product/productPDF_26513.pdf</span> </span></a></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></h4>
<ul>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">15</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">N de N<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O de O<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 15 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">40</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Ar/<sup>36</sup>Ar, </span></span>δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">40</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Ar/<sup>38</sup>Ar dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 20 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Δ</span></span><sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">17</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O de O<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">17</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O-excess de H<sub>2</sub>O (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
</ul>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;</span></span></strong><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;">:</span></span></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Frédéric Prié : <a href="mailto:frederic.prie@lsce.ipsl.fr">frederic.prie[a]lsce.ipsl.fr</a> </span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Amaelle Landais : <a href="mailto:Amaelle.Landais@lsce.ipsl.fr">Amaelle.Landais[a]lsce.ipsl.fr</a> <br /></span></span></p>]]></description>
			<category>Mesure du δ15N - N2, δ18O - O2, δ40Ar/36Ar, δ40Ar/38Ar et δ17O - O2 dans l’air (Delta V+)</category>
			<pubDate>Mon, 27 Jul 2015 13:15:00 +0000</pubDate>
		</item>
		<item>
			<title>Mesure du δ15N - N2, δ18O - O2, δ40Ar/36Ar, δ40Ar/38Ar et δ17O - O2 dans l’air (MAT 253)</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/20-fiche-6-mesure-du-d15n-n2-d18o-o2-d40ar-36ar-d40ar-38ar-et-d17o-o2-dans-l-air</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/20-fiche-6-mesure-du-d15n-n2-d18o-o2-d40ar-36ar-d40ar-38ar-et-d17o-o2-dans-l-air</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectromètre de masse à secteur magnétique MAT 253 / Possibilité de couplage avec lignes d’extraction, de purification et de fluorination</span></span></strong></span></h2>
<table style="margin-left: auto; margin-right: auto;">
<tbody>
<tr>
<td>
<p style="margin-bottom: 12pt;"><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche6.png" alt="fiche6" width="208" height="278" /></p>
</td>
<td>&nbsp;</td>
<td>
<p style="margin-bottom: 12pt;"><img src="https://panoply-geops.lsce.ipsl.fr/images/fiche6_bis.png" alt="fiche6 bis" width="365" height="274" /></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h2 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></h2>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Le principe du spectromètre de masse est basé sur l’ionisation dans la source, l’accélération par un champ électrique et la déviation en fonction de la masse par un champ magnétique. Différentes cages de Faraday sont placées en sortie et permettent de récupérer les masses 28, 29, 30&nbsp;; 32, 33, 34&nbsp;; 36, 38, 40&nbsp;; 82, 86. Il est équipé d’un module de double injection.</span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Cet instrument peut être couplé à une ligne d’extraction des gaz de la glace, à différents systèmes de purification de l’air utilisant des colonnes chromatographiques ou des systèmes d’adsorption et à une ligne de fluorination de l’eau. A la sortie de ces différentes lignes de préparation, les échantillons d’air purifié sont piégés dans l’hélium liquide et connectés au spectromètre de masse.</span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="font-family: Cambria; font-size: small;"><span style="font-size: 12pt;"><a href="http://www.thermoscientific.com/en/product/mat-253-stable-isotope-ratio-mass-spectrometer.html"><span class="Lienhype"><span style="text-decoration: underline;"><span style="color: blue; font-family: Arial;"><span style="font-family: 'Arial','sans-serif';">http://www.thermoscientific.com/en/product/mat-253-stable-isotope-ratio-mass-spectrometer.html</span></span></span></span></a></span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></h4>
<ul>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">15</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">N de N<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">18</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O de O<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 15 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">40</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Ar/<sup>36</sup>Ar, </span></span>δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">40</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">Ar/<sup>38</sup>Ar dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 20 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Δ<sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">17</span></span></sup><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O de O<sub>2</sub> dans l’air (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
<li style="margin-bottom: 0.0001pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><sup><span style="color: #1a1a1a;">17</span></sup><span style="color: #1a1a1a;"></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">O-excess de H<sub>2</sub>O (1</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> s</span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"> = 5 ppm)</span></span></span></li>
</ul>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;</span></span></strong><span style="color: #1a1a1a; font-family: Arial;"><span style="font-family: 'Arial','sans-serif'; color: #1a1a1a;">:</span></span></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Frédéric Prié : <a href="mailto:frederic.prie@lsce.ipsl.fr">frederic.prie[a]lsce.ipsl.fr</a> </span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Amaelle Landais : <a href="mailto:Amaelle.Landais@lsce.ipsl.fr">Amaelle.Landais[a]lsce.ipsl.fr</a></span></span><br /></span></span></p>]]></description>
			<category>Mesure du δ15N - N2, δ18O - O2, δ40Ar/36Ar, δ40Ar/38Ar et δ17O - O2 dans l’air (MAT 253)</category>
			<pubDate>Fri, 23 Oct 2015 06:20:59 +0000</pubDate>
		</item>
		<item>
			<title>Analyses du δ18O et δ13C dans des carbonates (15-50 microgrammes)</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/28-fiche-15-analyses-du-d18o-et-d13c-dans-des-carbonates</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/28-fiche-15-analyses-du-d18o-et-d13c-dans-des-carbonates</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectromètre de masse IRMS ISOPRIME 100<br /></span></span></strong></span></h2>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/Isoprime_100_20210827_120613-reduit.jpg" alt="figure14" width="500" height="375" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<p>&nbsp;</p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Spectromètre de masse IRMS ISOPRIME 100 est couplé à une ligne d’extraction. L’ensemble a été mis en service en 2014. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates, et en particulier les foraminifères benthiques et planctoniques. Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 15-200 microgrammes. La spécificité de ce spectromètre est la possibilité de mesurer un seul foraminifère (15 microgrammes).</span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry</span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.</span></span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></h4>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">D. Blamart : <a href="mailto:dominique.blamart@lsce.ipsl.fr">dominique.blamart[a]lsce.ipsl.fr</a><br /></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">P. Richard : <a href="mailto:patricia.richard@lsce.ipsl.fr">patricia.richard[a]lsce.ipsl.fr</a></span></p>]]></description>
			<category>Analyses du δ18O et δ13C dans des carbonates (15-50 microgrammes)</category>
			<pubDate>Tue, 27 Oct 2015 08:13:44 +0000</pubDate>
		</item>
		<item>
			<title>Analyses du δ18O et δ13C dans des carbonates </title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/29-fiche-16-analyses-du-d18o-et-d13c-dans-des-carbonates</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/29-fiche-16-analyses-du-d18o-et-d13c-dans-des-carbonates</guid>
			<description><![CDATA[<p style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectrometre de masse IRMS GV ISOPRIME<br /></span></span></strong></span></p>
<p>&nbsp;</p>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/Isoprime_GV_20210827_120613-reduit.jpg" alt="figure15" width="500" height="375" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<p>&nbsp;</p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt; color: #1a1a1a;">Spectromètre de masse IRMS GV ISOPRIME couplé à une ligne d’extraction. Il a été mis en service en 2006. Ce spectromètre est de type Dual Inlet. Il est dédié à l’analyses des (bio)carbonates : foraminifères bentiques et planctoniques, poudre de carbonates (spéléothèmes par exemple)... Les précisions sont de l’ordre de 0,08 et 0,05 respectivement pour l’oxygène et le carbone. La quantité de matériel nécessaire pour une mesure est de l’ordre de 40-100 microgrammes.</span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;"></span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">http://en.wikipedia.org/wiki/Isotope-ratio_mass_spectrometry</span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">Analyses isotopiques des carbonates, isotopes du carbone et de l’oxygène.</span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></p>
<p><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a;">D. Blamart : <a href="mailto:dominique.blamart@lsce.ipsl.fr">dominique.blamart[a]lsce.ipsl.fr</a></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">P. Richard : <a href="mailto:patricia.richard@lsce.ipsl.fr">patricia.richard[a]lsce.ipsl.fr</a><br /></span></p>]]></description>
			<category>Analyses du δ18O et δ13C dans des carbonates </category>
			<pubDate>Tue, 27 Oct 2015 08:37:52 +0000</pubDate>
		</item>
		<item>
			<title>Datation 40K/40Ar des laves et sur illites</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/31-fiche-18-datation-40k-40ar-des-laves-et-sur-illites</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/31-fiche-18-datation-40k-40ar-des-laves-et-sur-illites</guid>
			<description><![CDATA[<p style="text-align: center;"><span style="font-size: 14pt;"><strong>S3CC19&nbsp;: Spectromètre de masse à double collection, couplé à une ligne d'extraction (Four à induction) et de purification des gaz extraits de roches volcaniques</strong></span></p>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/figure_18.jpg" alt="figure 18" width="499" height="374" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></p>
<p><span style="font-size: 12pt;"><span style="font-family: arial, helvetica, sans-serif;">Spectromètre à source Nier équipé d'un détecteur double coupelle de Faraday permettant la collection simultanée d’40Ar et 36Ar. Il est conçu pour des mesures de haute précision des isotopes de l’Argon dans des échantillons terrestres et extra-terrestres. Le spectromètre est couplé à ligne de purification des gaz automatisée et équipée de getters GP10 et GP50, d’un sublimateur de titane, assurant la purification des gaz et de bas blancs de ligne. L’extraction des gaz des échantillons est faite par un four à induction et sera possible après développement par laser. Ce spectromètre et cette ligne sont dédiés à la mesure exclusive des isotopes de l’Argon</span><span style="font-family: Times New Roman;"><span style="font-family: 'Times New Roman', 'serif';"><span class="hps"><span style="font-family: arial, helvetica, sans-serif;">.</span> </span></span></span></span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">https://w3.lsce.ipsl.fr/Phocea/Vie_des_labos/Ast/ast_sstechnique.php?id_ast=55</span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Datation 40K/40Ar sur mésostase (Laves) et sur Illites.</span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Contacts&nbsp;: </span></span></strong></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">H.Guillou : <a href="mailto:herve.guillou@lsce.ipsl.fr">herve.guillou[a]lsce.ipsl.fr</a></span></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">V. Scao : <a href="mailto:vincent.scao@lsce.ipsl.fr">vincent.scao[a]lsce.ipsl.fr</a></span></p>]]></description>
			<category>Datation 40K/40Ar des laves et sur illites</category>
			<pubDate>Tue, 27 Oct 2015 08:51:00 +0000</pubDate>
		</item>
		<item>
			<title>Datation 40Ar/39Ar sur mésostase (Laves) et datation laser 40Ar/39Ar sur monocristal</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/32-fiche-19-datation-40ar-39ar-sur-mesostase-laves-et-datation-laser-40ar-39ar-sur-monocristal</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/32-fiche-19-datation-40ar-39ar-sur-mesostase-laves-et-datation-laser-40ar-39ar-sur-monocristal</guid>
			<description><![CDATA[<h2 style="margin-bottom: 12pt; text-align: center;"><span style="font-size: 14pt;"><strong><span style="font-family: Calibri;"><span style="font-family: 'Calibri', 'sans-serif'; font-weight: bold;">Spectromètre MICROMASS VG 5400 (mono-collection à multiplication d’électrons et compteur ions), couplé à une ligne permettant une fusion par four ou par laser des échantillons de roches et minéraux volcaniques</span></span></strong></span></h2>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/figure18.jpg" alt="figure18" style="display: block; margin-left: auto; margin-right: auto;" /></p>
<p>&nbsp;</p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Spectromètre à source Nier équipé d'un détecteur de type coupelle de Faraday et d’un multiplicateur d'électrons et compteur d’ions permettant des mesures de haute sensibilité de tous les gaz nobles (He, Ne, Ar, Kr et Xe). Il est conçu pour des mesures de haute précision de gaz rares dans des échantillons terrestres et extra-terrestres. Le spectromètre est couplé à ligne de purification des gaz automatisée et équipée de 4 getters (2 GP10 et 2 GP50 fonctionnant à chaudes) afin de s'assurer que le gaz introduit dans le spectromètre est propre et exempt de gaz actif. L’extraction des gaz des échantillons est faite soit avec un four à doubles parois refroidi à l’eau soit grâce à un laser C02. Ce spectromètre et cette ligne sont dédiés à la mesure exclusive des isotopes de l’Argon.</span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">https://w3.lsce.ipsl.fr/Phocea/Vie_des_labos/Ast/ast_sstechnique.php?id_ast=55</span></p>
<p style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></p>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Datation 40Ar/39Ar sur mésostase (Laves)&nbsp; et datation laser 40Ar/39Ar sur monocristal (Feldspaths potassiques, Micas, Amphiboles).</span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="color: #1a1a1a;"><span style="color: #1a1a1a; font-weight: bold;">Contacts&nbsp;:</span></span></strong></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">S. Nomade : <a href="mailto:sebastien.nomade@lsce.ipsl.fr">sebastien.nomade[a]lsce.ipsl.fr</a></span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"></span></span></span></p>
<p style="margin-bottom: 12pt;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;"><span style="color: #1a1a1a;">V. Scao : <a href="mailto:vincent.scao@lsce.ipsl.fr">vincent.scao[a]lsce.ipsl.fr</a></span></span><span style="color: #1a1a1a;"><span style="color: #1a1a1a;"></span></span></span></p>
<p style="margin-bottom: 12pt;"><span style="color: #1a1a1a; font-family: arial, helvetica, sans-serif; font-size: 12pt;"><span style="color: #1a1a1a;">H.Guillou : <a href="mailto:herve.guillou@lsce.ipsl.fr">herve.guillou[a]lsce.ipsl.fr</a></span></span></p>]]></description>
			<category>Datation 40Ar/39Ar sur mésostase (Laves) et datation laser 40Ar/39Ar sur monocristal</category>
			<pubDate>Tue, 27 Oct 2015 08:56:35 +0000</pubDate>
		</item>
		<item>
			<title>Analyses des isotopes de l’U, du Th, du Pb, du Ac, du Pa, du Ra, du Sr, du Nd du B et du Li dans différentes matrices naturelles (Carbonates, eaux et sédiments)</title>
			<link>https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/37-fiche-24-analyses-des-isotopes-de-l-u-du-th-du-pa-du-ra-du-sr-du-nd-du-b-et-du-li-dans-differentes-matrices-naturelles-carbonates-eaux-et-sediments</link>
			<guid isPermaLink="true">https://panoply-geops.lsce.ipsl.fr/index.php/toutes-les-fiches/37-fiche-24-analyses-des-isotopes-de-l-u-du-th-du-pa-du-ra-du-sr-du-nd-du-b-et-du-li-dans-differentes-matrices-naturelles-carbonates-eaux-et-sediments</guid>
			<description><![CDATA[<h2 style="text-align: center;"><span style="font-family: arial, helvetica, sans-serif; font-size: 14pt;"><strong><span style="font-weight: bold;">Spectromètre de masse à source «&nbsp;plasma&nbsp;» Double focalisation et Multi-collection</span></strong></span></h2>
<h2 style="text-align: center;"><span style="font-family: arial, helvetica, sans-serif; font-size: 14pt;"><strong><span style="font-weight: bold;">MC-ICPMS Neptune</span></strong><strong><span style="font-weight: bold;"> <em><sup><span style="font-style: italic;">Plus</span></sup></em> <em><span style="font-style: italic;">Thermofisher Scientific</span></em></span></strong></span></h2>
<table style="width: 754px; height: 355px;" align="center">
<tbody>
<tr>
<td><img src="https://panoply-geops.lsce.ipsl.fr/images/figure_23a.jpg" alt="figure 23a" /></td>
<td>&nbsp;</td>
<td>
<p style="margin-bottom: 0.35cm; line-height: 100%; text-align: center;">&nbsp;<i>(couplage LA-MC-ICPMS)</i></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><img src="https://panoply-geops.lsce.ipsl.fr/images/figure_23b.png" alt="figure 23b" /></p>
</td>
</tr>
<tr>
<td style="text-align: center;"><em><span style="font-family: Cambria; font-size: small;"><span style="font-size: 12pt; font-family: 'Cambria','serif'; font-style: italic;">MC-ICPMS Neptune <sup>Plus </sup> (2010) </span></span></em></td>
<td>&nbsp;</td>
<td>
<p style="text-align: center;"><em><span style="font-family: Cambria; font-size: small;"><span style="font-size: 12pt; font-style: italic;">Laser ESI –NWR 193 nm (2011)</span></span></em></p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Description de l’instrument&nbsp;:</span></span></strong></h4>
<p style="text-align: justify;"><span style="font-size: 12pt; font-family: arial, helvetica, sans-serif;"><strong><span style="font-size: small;"><span style="font-size: 12pt; font-weight: bold;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></span></strong>Le MC-ICPMS Neptune<sup><i>Plus</i></sup> est un spectromètre de masse à source «&nbsp;Plasma&nbsp;» d’argon (ICP) doté d’une double focalisation (champ électrostatique + champ magnétique) et d’une multi-collection (MC). Ce spectromètre de masse permet de caractériser avec une grande précision les systèmes isotopiques stables, radiogéniques ou radioactifs de nombreux éléments chimiques du Tableau Périodique présents dans des archives naturelles (eaux, carbonates, apatites, sédiments, sols, roches, etc.). Sa forte capacité d’ionisation liée à la source «&nbsp;Plasma&nbsp;» d’argon lui confère une grande sensibilité. Sa double focalisation assure une bonne transmission du faisceau d’ions et nous offre la capacité de travailler à basse, moyenne ou haute résolution (suppression de certaines interférences isobariques). Enfin son système de multi-détection, de grande stabilité, permet d’obtenir une excellente précision analytique sur les rapports isotopiques (reproductibilité externe allant de quelques dizaines de ppm au <i>sub-</i>‰ selon les systèmes isotopiques). Autre avantage, la source «&nbsp;plasma&nbsp;», ouverte à l’atmosphère, nous offre la possibilité d’introduire et d’analyser des échantillons sous forme liquide après chimie (micro-nébuliseurs, systèmes APEX ou ARIDUS) ou directement sur solides (couplage Ablation Laser). Ses principaux domaines d’application sont la géochronologie (datation U-Th), la géochimie marine et la paléocéanographie (isotopes du Pa, Th, U, Ra, Nd), l’étude du cycle de carbone dans l’océan et l’impact de l’acidification des océans (isotopes du B, Th, Si), le traçage de sources naturelles &amp; anthropiques, des applications en archéologie ou encore la caractérisation isotopique de roches volcaniques ou sédimentaires (isotopes du Nd, Sr, Pb voire Cu, Zn, Fe).</span></p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Principe de l’analyse&nbsp;:</span></span></strong></h4>
<p style="text-align: justify;"><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="font-weight: bold;">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; </span></strong>&nbsp;En solution, l’échantillon est aspiré et injecté par un nébuliseur sous forme de spray au cœur d’une source «&nbsp;Plasma&nbsp;» d’argon à 6000-8000°K sous pression atmosphérique. A cette température, les éléments présents sont ionisés. Transférés par une interface (cônes échantillonneur &amp; écrêteur), les ions sont accélérés sous vide primaire puis secondaire pour former un faisceau d’ion (énergie finale pouvant atteindre 10keV). Le faisceau est alors filtré en énergie (secteur électrostatique), puis en masse (secteur magnétique) selon le rapport m/z. En sortie du filtre en masse, les isotopes sont détectés par un système de multi-collecteurs doté de 15 détecteurs (9 cages de Faraday, 1 SEM et 5 CDD). Les isotopes sont alors mesurés simultanément sur plusieurs détecteurs permettant d’obtenir des rapports isotopiques de grande précision. Les précisions (ou reproductibilités externes) obtenues sur cage de Faraday pour les rapports isotopiques proches de l’unité sont de l’ordre de quelques dizaines de ppm pour les isotopes du Sr, Nd, de 0,05 à quelques 0,1&nbsp;‰ pour les isotopes du Li, B ou de l’ordre du 1 ‰ pour les systèmes de faible rapport isotopique, de l’ordre de 10<sup>-6</sup> (isotopes de l’U et du Th). Le faisceau d’ion en cage centrale peut basculer sur le compteur d’ions central (SEM) si le signal est trop faible permettant par exemple de mesurer les isotopes <sup>230</sup>Th et <sup>234</sup>U indispensables pour la datation U-Th. Pour certains systèmes isotopiques tels que ceux du Si, Fe ou plus généralement les métaux de transition, les mesures sont réalisées en haute résolution afin de séparer les isotopes analysés des potentielles interférences isobariques. Dans cette configuration, la taille du faisceau est diminuée en entrée grâce à un système de fente ce qui permet d’augmenter le pouvoir de résolution d’un facteur 10.</span></p>
<p style="text-align: justify;">&nbsp;</p>
<p style="text-align: justify;"><span style="font-size: 12pt; font-family: arial, helvetica, sans-serif;"> Les mesures isotopiques par MC-ICPMS sont relatives et nécessitent de faire référence à des standards du laboratoire ou internationaux dont les valeurs isotopiques sont connues et/ou certifiées (NIST). La méthode dite d’encadrement «&nbsp;bracketing&nbsp;» est généralement utilisée pour caractériser précisément la composition isotopique d’un élément étudié et prendre en compte les dérives instrumentales. Il est possible d’introduire dans la source plasma des solutions purifiées préalablement en salle blanche mais également un flux de gaz d’hélium entrainant des aérosols. Des mesures isotopiques de certaines éléments comme le Sr, le B ou l’U dans les carbonates peuvent être réalisées après couplage avec l’ablation laser Excimer NWR193 nm.</span></p>
<p style="text-align: justify;"><span style="font-family: Calibri; font-size: small;"><span style="font-size: 12pt; font-family: 'Calibri','sans-serif';">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; <em></em></span></span></p>
<p><span style="font-family: arial, helvetica, sans-serif;"><strong><em><span style="font-size: small;"><span style="font-size: 12pt; font-weight: bold; font-style: italic;">Périphériques ou autres particularités </span></span></em></strong></span></p>
<ul>
<li>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Nébuliseurs type PFA 20, 50 ou 100 µL/min et chambre micro-cyclonique&nbsp;(solutions) ;</span></p>
</li>
<li>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Systèmes de dé-solvatation&nbsp;APEX Omega et Omega HF et ARIDUS II + QuickWash (gain en sensibilité par un facteur 2 à 10 selon les éléments&nbsp;; solutions)&nbsp;;</span></p>
</li>
<li>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Jet-Interface installée en 2014 (gain en sensibilité, facteur 2 à 5 selon les éléments, solutions)&nbsp;;</span></p>
</li>
<li>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Système d’ablation laser Excimer ESI – NWR 193 nm (mesures <em><span style="font-style: italic;">in-situ</span></em>, aérosols issus de solides).</span></p>
</li>
</ul>
<p>&nbsp;</p>
<h4 style="margin-bottom: 12pt;"><strong><span style="color: #1a1a1a; font-family: Arial; font-size: small;"><span style="font-size: 12pt; font-family: 'Arial','sans-serif'; color: #1a1a1a; font-weight: bold;">Analyses réalisées sur l’instrument&nbsp;:</span></span></strong></h4>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><em><span style="font-style: italic;">Solutions </span></em><em><span style="font-style: italic;">(après chimie)</span></em></span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Isotopes de l’U, du Th, du Pa, du Ra (datations U-Th, géochimie marine ou continentale)&nbsp;; </span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Isotopes du Sr, du Nd dans différentes matrices naturelles (traçage de sources, érosion, dynamique océanique, études archéologiques)&nbsp;;</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Isotopes du B et du Li dans les carbonates et les eaux (paléo-pH &amp; cycle du carbone, biogéochimie marine)&nbsp;;</span></li>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Autres systèmes isotopiques étudiés&nbsp;: Si, Fe, Cu, Zn, etc.</span></li>
</ul>
<p><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;"><em><span style="font-style: italic;">Solide par Ablation laser </span></em><em><span style="font-style: italic;">(en cours de développement) </span></em></span></p>
<ul>
<li><span style="font-family: arial, helvetica, sans-serif; font-size: 12pt;">Isotopes du B (<strong>δ</strong><sup>11</sup>B), du Sr (<sup>87</sup>Sr/<sup>86</sup>Sr) et de l’U (<strong>δ</strong><sup>234</sup>U) dans les carbonates et silicates.</span></li>
</ul>
<p>&nbsp;</p>
<h4><span style="color: #000000; font-family: arial, helvetica, sans-serif; font-size: 12pt;"><strong><span style="font-weight: bold;">Contacts&nbsp;:</span></strong></span></h4>
<p class="western" style="margin-bottom: 0.35cm; line-height: 100%;"><span style="font-size: 12pt; font-family: arial, helvetica, sans-serif;"><i><b>Responsable instrumental :&nbsp; </b></i>Arnaud Dapoigny <a href="mailto:arnaud.dapoigny@lsce.ipsl.fr"><span style="color: #0000ff;"><span style="text-decoration: underline;">arnaud.dapoigny[a]lsce.ipsl.fr</span></span></a> 01 69 08 04 70<br /></span></p>
<p class="western" style="margin-bottom: 0.35cm; line-height: 100%;"><span style="font-size: 12pt; font-family: arial, helvetica, sans-serif;"><i><b>Responsable scientifique :&nbsp; </b></i>Eric Douville (B, Li, Sr) <span style="color: #0000ff;"><span style="text-decoration: underline;"><a href="mailto:eric.douville@lsce.ipsl.fr">eric.douville[a]lsce.ipsl.fr</a></span></span> 01 69 08 22 57<br /></span></p>
<p class="western" style="margin-bottom: 0.35cm; line-height: 100%;"><span style="font-size: 12pt; font-family: arial, helvetica, sans-serif;"><i><b>Autres scientifiques GEOPS-LSCE impliqués :&nbsp; </b></i>Christophe Colin (Nd, Sr), Edwige Pons-Branchu (U, Th, Ra, Sr, Pb), Claire Rollion-Bard &amp; François Thil (couplage <i>Laser</i>), William Gray (B), Damien Guinoiseau (Pb).</span></p>]]></description>
			<category>Analyses des isotopes de l’U, du Th, du Pb, du Ac, du Pa, du Ra, du Sr, du Nd du B et du Li dans différentes matrices naturelles (Carbonates, eaux et sédiments)</category>
			<pubDate>Tue, 27 Oct 2015 12:16:16 +0000</pubDate>
		</item>
	</channel>
</rss>
